STRADDLE R290 CHILLER ATSTN050U MONOBLOCK 7.0 m³ UNIT
Click Image for Gallery
Technical DATA for ATSTN050U
TECHNICAL DATA UNIT
• Cold room temperature: +5 ÷ -5°C
- Form: 1S
- Voltage (V/ph/Hz): 230/1/50
- Max. elec. absorp. in running condition kW: 0.82
- Compressor Type: E
- Displacement: m3/h - 50Hz: 2.52 | m3/h - 60Hz: 3.05
- Absorption during defrost kW: 0.86
- Refrigerant quantity kg: 0.13
CONDENSER:
- Fin pitch: 3.2
- Fans: 1x254
- Fan absorption: 1x32
- Airflow: 720
EVAPORATOR
- Fin pitch: 4.2
- Fans: 1x230
- Fan absorption: 1x24
- Airflow: 600
- Air-throw: 6
Refrigerating capacity (W) - Room volume (m3)
* Cold room temperature: + 5 °C
- Ambient temperature: + 32 °C
- Unit Capacity: 10.0 m3
* Cold room temperature: 0 °C
- Ambient temperature: + 32 °C
- Unit Capacity: 7.0 m3
* Cold room temperature: - 5 °C
- Ambient temperature: + 32 °C
- Unit Capacity: 5.0 m3